100A Electrical Panel Load Calculator

Estimate whether your panel has capacity for an EV charger or electric heat pump using the NEC 220.82 optional method.

Your home & planned loads

Adjust the starting values to match your home.

Fixed appliances

Select appliances in the home. Values can be adjusted under Advanced.

Advanced: edit appliance VA

Estimated panel load

Calculated demand compared with panel rating

SAFE
—A of 100A

Likely Has Headroom

0APanel limit 100A

0% of panel rating

Load breakdown

General + fixed demand
— VA
Largest HVAC load
— VA
EV charger
— VA
Total calculated load
— VA

Common questions

EV charger & panel load FAQs

Can a 100-amp panel handle a Level 2 EV charger?

Yes, in many homes. Setting charging current to 16A–32A or using NEC-compliant EV load management can make room without upgrading to 200A; an electrician must verify the service calculation and equipment compatibility.

How does the NEC 220.82 optional load calculation work?

It starts with 3 VA per square foot plus 4,500 VA, then adds selected fixed appliances. The first 10,000 VA counts at 100% and the remainder at 40%, followed by the largest HVAC load and EV charger at 100%.

Do I have to upgrade to a 200A panel if my calculation is over 100A?

No. NEC 750.30 and 625.42 provide for properly applied energy-management options, which may include dynamic load-balancing chargers, compatible dryer splitters such as NeoCharge, or load-shedding boxes such as DCC-12. An electrician and local AHJ must confirm equipment listing, installation, and acceptance.

Is a 16A or 24A EV charger fast enough for daily driving?

A 16A charger adds about 12 miles of range per charging hour, while 24A adds about 18 miles per hour. Over an 8–10-hour overnight charge, that is roughly 96–180 miles—enough for many US commuters, depending on the vehicle and conditions.

Does this calculator replace a licensed electrician's load calculation?

No. This is an educational pre-check, not a permit calculation or substitute for a complete load calculation by a licensed electrician. Local AHJ requirements and utility rules vary.

This estimate is not a permit calculation or a substitute for a complete load calculation.